UL Recognitions
File: E37151 – Temperature Indicating and Regulating Equipment.
Category: Temperature Limiting or Limiting and Regulating Equipment.
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
A, AA | 120 VAC | 3 | Resistive | 150 | 100000 |
A1R, AA1R | 125 VAC | 2 | Resistive | 150 | 100000 |
A1R, AA1R | 125 VAC | 2 | Inductive | 150 | 100000 |
A2, AA2, -A2, -AA2 | 125 VAC | 5 | Resistive | 200 | 100000 |
A2R, AA2R | 125 VAC | 5 | Resistive | 200 | 100000 |
A3, AA3 | 125 VAC | 6 | Resistive | 200 | 100000 |
B | 125 VAC | 8 | Resistive | 150 | 100000 |
C, CH, -C, -CH | 120 VAC | 6 | Resistive | 200 | 100000 |
CR, CHR, -CR, -CHR | 120 VAC | 6 | Resistive | 200 | 100000 |
E | 125 VAC | 2 | Resistive | 90 | 100000 |
E1 | 125 VAC | 5 | Resistive | 180 | 100000 |
H | 36 VDC | 1 | Resistive | 220 | – |
H3 | 250 VAC | 10 | Resistive | 240 | – |
H3 | 24 VDC | 2 | Resistive | 240 | – |
H4 | 50 VDC | 0.5 | Resistive | 240 | – |
H5 | 250 VAC | 15 | Resistive | 240 | – |
H7 | 250 VAC | 15 | Resistive | 280 | – |
H8 | 250 VAC | 15 | Resistive | 280 | – |
J(A) | 120 VAC | 5 | Resistive | 150 | 100000 |
J(A) | 240 VAC | 4 | Resistive | 150 | 100000 |
J-2 | 120 VAC | 15 | Resistive | 160 | 6000 |
J(S) | 120 VAC | 15 | Non-Inductive | 150 | 6000 |
J(S) | 240 VAC | 13 | Non-Inductive | 150 | 6000 |
K, KH, KR, -K, -KH | 120 VAC | 3 | Resistive | 200 | 100000 |
W030 | 120 VAC | 20 | Resistive | 150 | 100000 |
W030 | 240 VAC | 10 | Resistive | 150 | 100000 |
File: E37151 – Temperature Indicating and Regulating Equipment
Category: Temperature Regulating Applications
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
A, AA | 120 VAC | 3 | Resistive | 150 | 100000 |
A1R, AA1R | 125 VAC | 3 | Resistive | 150 | 100000 |
A1R, AA1R | 125 VAC | 2 | Inductive | 150 | 100000 |
A2, AA2, -A2, -AA2 | 125 VAC | 5 | Resistive | 200 | 100000 |
A3, AA3 | 125 VAC | 7 | Resistive | 200 | 100000 |
B | 120 VAC | 12 | Resistive | 150 | 100000 |
B | 240 VAC | 8 | Resistive | 150 | 100000 |
C, CH, -C, -CH | 240 VAC | 4 | Resistive | 200 | 100000 |
CR, CHR, -CR, -CHR | 240 VAC | 4 | Resistive | 200 | 100000 |
K, KH, KR, -K, -KH | 120 VAC | 4 | Resistive | 200 | 100000 |
K, KH, KR, -K, -KH | 240 VAC | 2 | Resistive | 200 | 100000 |
W030 | 120 VAC | 20 | Resistive | 150 | 100000 |
W030 | 240 VAC | 10 | Resistive | 150 | 100000 |
File: E37151 – Temperature Indicating and Regulating Equipment
Category: Direct Current Contact Ratings
Note: All models have been found to be compliant to CSA requirements.
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
A2 | 12 VDC | 6 | Resistive | 100 | 5000 |
C | 12 VDC | 8 | Resistive | 100 | 5000 |
C | 24 VDC | 4 | Resistive | 100 | 5000 |
C, CH | 24 VDC | 1 | Resistive | 220 | 5000 |
F | 12 VDC | 10 | Resistive | 100 | 5000 |
F-1 | 12 VDC | 10 | Resistive | 100 | 5000 |
F-2 | 12 VDC | 10 | Resistive | 100 | 5000 |
J(A) | 12 VDC | 10 | Resistive | 100 | 10000 |
J(A) | 24 VDC | 5 | Resistive | 100 | 10000 |
J(B) | 12 VDC | 10 | Resistive | 100 | 10000 |
J(B) | 24 VDC | 5 | Resistive | 100 | 10000 |
J(D) | 12 VDC | 10 | Resistive | 100 | 10000 |
J(D) | 24 VDC | 5 | Resistive | 100 | 10000 |
J(E) | 12 VDC | 10 | Resistive | 100 | 10000 |
J(E) | 24 VDC | 5 | Resistive | 100 | 10000 |
J(F) | 12 VDC | 10 | Resistive | 100 | 10000 |
J(F) | 24 VDC | 5 | Resistive | 100 | 10000 |
J(J) | 12 VDC | 10 | Resistive | 100 | 10000 |
J(J) | 24 VDC | 5 | Resistive | 100 | 10000 |
N | 12 VDC | 8 | Resistive | 100 | 5000 |
N | 24 VDC | 4 | Resistive | 100 | 5000 |
N-1 | 12 VDC | 8 | Resistive | 100 | 5000 |
N-1 | 24 VDC | 4 | Resistive | 100 | 5000 |
N-2 | 12 VDC | 8 | Resistive | 100 | 5000 |
N-2 | 24 VDC | 4 | Resistive | 100 | 5000 |
V | 12 VDC | 10 | Resistive | 100 | 5000 |
V | 24 VDC | 5 | Resistive | 100 | 5000 |
File: E37151 – Temperature Indicating and Regulating Equipment
Category: Thermal Protector For Use In Electric Heating Pads.
Note: Testing conducted per Standards of UL 130 for a minimum or 100,000 cycles or 1,000 hours of continuous cycling, whichever is greater.
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
A, AA | 125 VAC | 2 | Resistive | 120 | 100000 |
A1, AA1 | 125 VAC | 1 | Resistive | 120 | 100000 |
-A2, -AA2 | 125 VAC | 5 | Resistive | 120 | 100000 |
E | 125 VAC | 2 | Resistive | 90 | 100000 |
File: E37151 – Temperature Indicating and Regulating Equipment
Category: Thermal Protector For Use In Fluorescent Lamp Ballasts
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
F | 277 VAC | 5 | Inductive | 130 | 10000 |
J(D) | 120 VAC | 5.5 | Inductive | 120 | 10000 |
J(D) | 277 VAC | 1.75 | Inductive | 120 | 10000 |
File: E37151 – Temperature Indicating and Regulating Equipment
Category: Thermal Protector For Use In Incandescent Lamps
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes/Watts) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
F | 120 | 500 W | Tungsten | 150 | 10000 |
J(D) | 120 | 500 W | Tungsten | 160 | 10000 |
-A2, -AA2 | 125 VAC | 5 | Resistive | 120 | 100000 |
E | 125 VAC | 2 | Resistive | 90 | 100000 |
File: E37151 – Temperature Indicating and Regulating Equipment
Category: Thermal Protector For Use In Radio and TV Transformers
Note: Thermal protectors are run for 6,000 cycles or 15 days, whichever is greater. Protectors are tested per UL 1416;
Overcurrent and Overtemperature Protectors for use in Radio & TV Transformers.
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (# of Cycles) |
A, AA | 120 VAC | 3 | Inductive | 150 | 6000 |
A1, AA1 | 120 VAC | 2 | Inductive | 120 | 6000 |
A2, AA2, -A2, -AA2 | 120 VAC | 4 | Inductive | 200 | 6000 |
J(D) | 120 VAC | 5 | Inductive | 135 | 6000 |
File: E42562 Motor Protective Devices, Inherent Overheating
Note: All models recognized under E 42652 have been evaluated for limited short circuit only per UL 547. The
suggested ratings provided in this chart have been determined through past end product approvals and are
provided as reference purposes only.
|
Maximum Ratings | ||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (ºC) |
Endurance (as noted) |
A, AA | 120 VAC | 4 | Inductive | 150 | 18 Days |
A, AA | 240 VAC | 2 | Inductive | 150 | 18 Days |
A2, AA2, -A2, -AA2 | 120 VAC | 5 | Inductive | 150 | 18 Days |
A2, AA2, -A2, -AA2 | 240 VAC | 2 | Inductive | 150 | 18 Days |
B | 120 VAC | 6 | Inductive | 150 | 18 Days |
B | 240 VAC | 3 | Inductive | 150 | 18 Days |
C, CH, -C, -CH | 120 VAC | 5 | Inductive | 150 | 18 Days |
C, CH, -C, -CH | 240 VAC | 2.5 | Inductive | 150 | 18 Days |
F | 120 VAC | 12 | Inductive | 150 | 18 Days |
F | 240 VAC | 8 | Inductive | 150 | 18 Days |
F-1, F-2 | 120 VAC | 12 | Inductive | 160 | 18 Days |
F-1, F-2 | 240 VAC | 8 | Inductive | 160 | 18 Days |
FC-M1D, FC-2PD | 125 VAC | 12 | Inductive | 150 | 6,000 Cycles |
FC-M1D, FC-2PD | 250 VAC | 8 | Inductive | 150 | 6,000 Cycles |
G | 120 VAC | 2 | Inductive | 150 | 18 Days |
G | 240 VAC | 4 | Inductive | 150 | 18 Days |
JCA, JCB | 115 VAC | 22 | Inductive | 150 | 6,000 Cycles |
JCA, JCB | 250 VAC | 8 | Inductive | 150 | 6,000 Cycles |
J(B) | 120 VAC | 15 | Inductive | 160 | 18 Days |
J(B) | 240 VAC | 10 | Inductive | 160 | 18 Days |
J(D) | 120 VAC | 15 | Inductive | 150 | 18 Days |
J(D) | 240 VAC | 10 | Inductive | 150 | 18 Days |
J(E) | 120 VAC | 15 | Inductive | 150 | 18 Days |
J(E) | 240 VAC | 10 | Inductive | 150 | 18 Days |
J(F) | 120 VAC | 15 | Inductive | 155 | 18 Days |
J(F) | 240 VAC | 10 | Inductive | 155 | 18 Days |
J(H) | 120 VAC | 15 | Inductive | 155 | 18 Days |
J(H) | 240 VAC | 10 | Inductive | 155 | 18 Days |
J(J) | 120 VAC | 15 | Inductive | 150 | 18 Days |
J(J) | 240 VAC | 10 | Inductive | 150 | 18 Days |
J(S) | 120 VAC | 15 | Inductive | 150 | 6,000 Cycles |
J(S) | 240 VAC | 10 | Inductive | 150 | 6,000 Cycles |
K, KH, -K, -KH | 120 VAC | 4 | Inductive | 150 | 18 Days |
K, KH, -K, -KH | 240 VAC | 2 | Inductive | 150 | 18 Days |
L | 120 VAC | 8 | Inductive | 150 | 18 Days |
L | 240 VAC | 4 | Inductive | 150 | 18 Days |
R | 120 VAC | 6 | Inductive | 150 | 18 Days |
R | 240 VAC | 3 | Inductive | 150 | 18 Days |
W 030 | 120 VAC | 50 | Inductive | 150 | 18 Days |
W 030 | 240 VAC | 37 | Inductive | 150 | 18 Days |
W 100 | 120 VAC | 50 | Inductive | 150 | 18 Days |
W 100 | 240 VAC | 37 | Inductive | 150 | 18 Days |
W 150 | 120 VAC | 50 | Inductive | 150 | 18 Days |
W 150 | 240 VAC | 37 | Inductive | 150 | 18 Days |
W 200 | 120 VAC | 50 | Inductive | 150 | 18 Days |
W 200 | 240 VAC | 37 | Inductive | 150 | 18 Days |
W 300 | 120 VAC | 50 | Inductive | 150 | 18 Days |
W 300 | 240 VAC | 37 | Inductive | 150 | 18 Days |
W 400 | 120 VAC | 50 | Inductive | 150 | 18 Days |
W 400 | 240 VAC | 37 | Inductive | 150 | 18 Days |